TaFlux ETV Series
General Information
TaFlux ETV series uf modules are pressurized UF modules, which are designed and manufactured for the filtration of surface water, potable water, seawater and industrial wastewater. These UF modules are made of new generation PVDF hollow fiber membrane with high fouling resistance and hydrophilicity.TaFlux ETV series UF modules are applied in new systems, as well as directly connected to existing UF systems as replacements, providing high-quality filtrate by removing suspended solids, colloids, pyrogens, bacteria, viruses and other impurities to protect downstream processes.
Features
- Outside-to-inside flow direction
- New generation PVDF hollow fiber
- Nominal pore size of 0.025 μm
- Typical filtrate quality SDI ≤ 2.5, turbidity ≤ 0.1 NTU
Advantages
- High quality raw material
- High thermal and chemical solvent resistance
- High chemical tolerance for cleaning
- Optimized design, high resistance to fouling
- Economical equivalent UF modules for direct replacement
Applications
- Surface water
- Potable water
- Pre-treatment of seawater desalination
-
Pre-treatment of industrial water
- Industrial wastewater
Module Dimensions
Model |
L |
L1 |
D |
D1 |
Feed, Filtrate, Concentrate |
TFETV-32 TFETV-40 |
1,600 mm (62.99 inch) |
316 mm (12.44 inch) |
344 mm (13.54 inch) |
216 mm (8.5 inch) |
1.5” FNPT |
TFETV-55 TFETV-60 |
2,340 mm (92.13 inch) |
Specifications
Model |
TFETV-32 |
TFETV-40 |
TFETV-55 |
TFETV-60 |
Effective membrane area |
32 m² (345 ft²) |
40 m² (430 ft²) |
55 m² (592 ft²) |
60 m² (645 ft²) |
Membrane material |
PVDF (Polyvinylidene Fluoride) |
|||
Fiber ID/OD |
0.7/1.3 mm (0.02/0.05 inch) |
|||
Flow direction |
Outside-in |
|||
Pore size |
0.025 μm |
|||
Bacteria removal |
> 99.9999% |
|||
Housing material |
UPVC |
|||
End caps material |
UPVC |
|||
Potting material |
Polyurethane resin |
|||
O-rings material |
EPDM |
|||
Dry weight |
50 KG (110 lbs) |
60 KG (132 lbs) |
||
Wet weight filled with water |
90 KG (198 lbs) |
100 KG (221 lbs) |
Operating and Cleaning Limits
Type of operation |
Dead-end flow or cross flow |
Design flux (25°C) |
60 - 120 L/m2·h (35 - 71 gfd) |
Temperature |
5 - 40°C (41 - 104°F) |
Maximum feed pressure (20°C) |
2.5 bar (36.2 psi) |
Maximum trans-membrane pressure |
2 bar (29 psi) |
Backwash flux (25°C) |
80 - 120 L/m2·h (48 - 71 gfd) |
Maximum backwash pressure |
2 bar (29 psi) |
Maximum air scour feed pressure |
2.5 bar (36.2 psi) |
Maximum air scour flow |
4 - 12 Nm3/h (2.4 - 7.1 scfm) |
pH continuous operation @ 25°C |
2 - 11 |
pH cleaning @ 25°C |
1 - 12 |
Maximum NaClO (continuous operation) |
30 mg/L |
Maximum NaClO (cleaning) |
5,000 mg/L |
Maximum feed TSS |
100 ppm |
Maximum feed turbidity |
300 NTU |
Maximum feed particle size |
300 µm |
Filtrate SDI15 |
≤ 2.5 |
Filtrate turbidity |
≤ 0.1 NTU |